Files
50ohm-contents-dl/contents/slides/sakringar.md
T
SuperminarenandClaude Sonnet 5.5 f7fa8cfbc1 Swedish adaptation: Instegscertifikat and HAREC content
- Sections and slides rewritten in Swedish; German law and institutions replaced by
  Swedish/CEPT/ITU equivalents (PTS, SSA, PTSFS 2025:1, SSMFS 2008:18), unverified
  statements marked "% TODO VERIFY"
- New toc: INSTEG, HAREC, UPPGRADERING; section idents are Swedish (see ident-map.tsv)
- Exam-question tags, BNetzA question pool, solutions and the German SWL course removed
- Static pages, snippets, applets, READMEs and image alt-texts translated
- TikZ labels translated; SVG drawings regenerated (drawing 689 still fails to build
  upstream: it references a missing photo)
- Changed from the original: not endorsed by DARC e.V., SSA or PTS

Co-Authored-By: Claude Sonnet 5.5 <[email protected]>
2026-10-10 15:03:03 +02:00

23 lines
848 B
Markdown

<left>
* I nätaggregatet och/eller i förbindelsekabeln till transceivern finns så kallade finsäkringar
* De bryter strömmen vid fel (kortslutning eller överbelastning)
</left>
<right>
[photo:88:n_feinsicherungen:Finsäkringar]
</right>
---
* När en finsäkring har löst ut och man åtgärdat orsaken måste den bytas.
* Defekta säkringar får *bara ersättas med likadana*!
* Man måste ta hänsyn både till *strömstyrka* och *utlösningskarakteristik*, som anger hur snabbt en säkring löser ut (snabb, medeltrög, trög).
---
| c: Utlösningskarakteristik | c: Beteckning | c: Frånkopplingstid vid tio gånger märkströmmen |
| snabb | F | max. $\qty{30}{\milli\second}$ |
| medeltrög | MT | max. $\qty{90}{\milli\second}$ |
| trög | T | max. $\qty{300}{\milli\second}$ |
[table:n_feinsicherung:Egenskaper hos finsäkringar]