- Sections and slides rewritten in Swedish; German law and institutions replaced by Swedish/CEPT/ITU equivalents (PTS, SSA, PTSFS 2025:1, SSMFS 2008:18), unverified statements marked "% TODO VERIFY" - New toc: INSTEG, HAREC, UPPGRADERING; section idents are Swedish (see ident-map.tsv) - Exam-question tags, BNetzA question pool, solutions and the German SWL course removed - Static pages, snippets, applets, READMEs and image alt-texts translated - TikZ labels translated; SVG drawings regenerated (drawing 689 still fails to build upstream: it references a missing photo) - Changed from the original: not endorsed by DARC e.V., SSA or PTS Co-Authored-By: Claude Sonnet 5.5 <[email protected]>
848 B
848 B
* I nätaggregatet och/eller i förbindelsekabeln till transceivern finns så kallade finsäkringar
* De bryter strömmen vid fel (kortslutning eller överbelastning)
[photo:88:n_feinsicherungen:Finsäkringar]
- När en finsäkring har löst ut och man åtgärdat orsaken måste den bytas.
- Defekta säkringar får bara ersättas med likadana!
- Man måste ta hänsyn både till strömstyrka och utlösningskarakteristik, som anger hur snabbt en säkring löser ut (snabb, medeltrög, trög).
| c: Utlösningskarakteristik | c: Beteckning | c: Frånkopplingstid vid tio gånger märkströmmen |
| snabb | F | max. \qty{30}{\milli\second} |
| medeltrög | MT | max. \qty{90}{\milli\second} |
| trög | T | max. \qty{300}{\milli\second} |
[table:n_feinsicherung:Egenskaper hos finsäkringar]