fix, slides: get rid of \nonumber commands
We do not need the equation environment. It introduces the equation numbering, which we then disable by `\nonumber`. We just need the split-environment.
This commit is contained in:
@@ -28,7 +28,7 @@ Der angezeigte Messwert unterscheidet sich meist vom tatsächlichen Wert
|
||||
* gesucht: Abweichung der Leistung $P = U \cdot I$
|
||||
|
||||
<fragment>
|
||||
$\begin{equation}\begin{split} \nonumber P_{\textrm{Abw}} &= 100\% - (U_{\mathrm{Abw}} \cdot I_{\mathrm{Abw}})\\ &= 100\% - (95\% \cdot 95\%)\\ &= 100\% - 90,25\%\\ &= 9,75\% \end{split}\end{equation}$
|
||||
$\begin{split} P_{\textrm{Abw}} &= 100\% - (U_{\mathrm{Abw}} \cdot I_{\mathrm{Abw}})\\ &= 100\% - (95\% \cdot 95\%)\\ &= 100\% - 90,25\%\\ &= 9,75\% \end{split}$
|
||||
</fragment>
|
||||
|
||||
---
|
||||
@@ -47,6 +47,6 @@ $\begin{equation}\begin{split} \nonumber P_{\textrm{Abw}} &= 100\% - (U_{\mathrm
|
||||
* gesucht: $I$
|
||||
|
||||
<fragment>
|
||||
$\begin{equation} \nonumber I = \frac{U}{R} = \frac{0,5V}{10M\Omega} = 50nA \end{equation}$
|
||||
$$I = \frac{U}{R} = \frac{0,5V}{10M\Omega} = 50nA$$
|
||||
</fragment>
|
||||
|
||||
|
||||
Reference in New Issue
Block a user